The Multitone measurement can be configured by means of the softkeys and hotkeys in the graphical measurement menu.
AF Chan. |
The AF Chan. One softkey controls the Multitone
measurement and indicates its status (RUN | HLT | OFF). This status
can be changed after softkey selection (pressing once) by means of the
ON/OFF key or the CONT/HALT key.
AF Chan. One changes to AF Chan. Two if the corresponding application is selected. |
Remote control | |
Measurement configuration | Pressing the AF Chan. One softkey twice opens the popup menus Multitone Configuration (see Measurement Control (Audio Multitone Configuration - Control)). Besides, a number of hotkeys defining the scope of the measurement are associated with the AF Chan. One softkey. All settings are also provided in the Control tab of the Multitone Configuration menu; see section Measurement Control (Audio Multitone Configuration - Control). |
Application |
The Application softkey activates one of the applications of the Multitone measurement. The two applications represent two independent audio circuits. Both circuits are identical except for the input and output connectors. Configurations such as the input path (Analyzer Level) can be set independently. Changing the application will also change the measurement control softkey AF Chan. One / AF Chan. Two. |
AF Chan. One |
The AF Chan. One hotkey selects the Multitone measurement on channel one. This means that the audio signals are applied to the connectors AF IN (CMU input) and AF OUT (CMU output) on the front panel. |
Remote control | |
AF Chan. Two |
The AF Chan. Two hotkey selects the Multitone measurement on channel two. This means that the audio signals are applied to the connectors AUX 1 (CMU input) and AUX 2 (CMU output) on the CMU front panel. |
Remote control | |
Analyzer Level |
The Analyzer Level softkey controls the level in the AF input signal path for both applications of the Multitone measurement. |
AF Max. Level |
The AF Max. Level hotkey sets the maximum expected input level in mV. Two independent values can be set for the two applications AF Chan. One (Analyzer 1) and AF Chan. Two (Analyzer 2). The setting is applied if the AF Mode (see softkey below) is set to Manual. |
Note: The AF Max. Level setting supersedes the corresponding level set in the Control tab of the Analyzer Configuration menu; see section Measurement Control (Analyzer Configuration - Control). | |
Remote control | |
AF Mode |
The AF Mode hotkey determines how the input level is defined. |
Manual | Manual input via AF Max. Level hotkey |
Auto | Automatic setting according to the average power of the applied AF signal. |
Two independent values can be set for the two applications AF Chan. One (Analyzer 1) and AF Chan. Two (Analyzer 2). | |
Note: The AF Mode setting supersedes the corresponding setting in the Control tab of the Analyzer Configuration menu; see section Measurement Control (Analyzer Configuration - Control). | |
Remote control | |
Generator |
The Generator Level softkey defines the level of the
AF multitone signal.
The generator level settings are described in more detail in section Test Tones (Multitone Configuration - Tone Def.). |
Display |
The Display softkey scales or shifts the graphical display. |
Level Scale |
The Level Scale hotkey defines the level scale of
the Multitone test diagram (ordinate scale). The level scale merely
represents a display configuration that doesn't have any impact on the
measurement or on the input signal path.
The level scale is calculated from a maximum value (Max.) and a Span:
|
Remote control | |
Tone Scale |
The Tone Scale hotkey selects the display range (abscissa scale) of the test diagram. The range comprises 14 test tones which must be in consecutive order. This condition leaves the following options: |
Tone 1 to 14 ....
Display all results between tone 1 and tone 14 | |
Tone 7 to 20
Display all results between tone 7 and tone 20 | |
If a tone is within the selected range but disabled in the Tone Def. tab of the configuration menu (see section Test Tones (Multitone Configuration - Tone Def.)), the corresponding result is not indicated, i.e. the bar is omitted and a gap occurs in the test diagram. | |
Remote control | |
Default Scale |
The Default Scale hotkey cancels all display configurations made and activates the default settings. |
Remote control | |
Menus |
The Menus softkey displays the hotkey bar for switching over to the other measurement menus. |