CONFigure:MULTitone:AF1Channel:LIMit:LINE:ASYMmetric:LOWer
CONFigure:MULTitone:AF2Channel:LIMit:LINE:ASYMmetric:LOWer
<Limit_1>, <Enable_1>, ... <Limit_20>, <Enable_20>
<Limit_nr> |
Description of parameters |
Def. value |
Def. unit |
-80 dB to +80 dB, |
Lower limit line at tone <nr> |
See below |
dB |
<Enable_nr> |
Description of parameters |
Def. value |
Def. unit |
ON | OFF |
Enable lower limit line at tone <nr> |
ON |
- |
Description of command |
FW vers. |
This command configures the lower limit lines and enables the limit check at the 20 test tones that can be defined via |
V 3.0 |
By default, the limit check is switched on at all tones and the following limit lines apply: | |||||
Tone <nr> | Limit Line/[dB] | Enable | Tone <nr> | Limit Line/[dB] | Enable |
1 | -13.5 | ON | 11 | +1.6 | ON |
2 | -10.2 | ON | 12 | +2.3 | ON |
3 | -7.8 | ON | 13 | +2.9 | ON |
4 | -5.9 | ON | 14 | +3.5 | ON |
5 | -4.3 | ON | 15 | +4.0 | ON |
6 | -3.0 | ON | 16 | +4.6 | ON |
7 | -1.9 | ON | 17 | +5.0 | ON |
8 | -0.9 | ON | 18 | +5.0 | ON |
9 | 0.0 | ON | 19 | +5.0 | ON |
10 | +0.8 | ON | 20 | +5.0 | ON |