Stop condition: NONE
|
A single shot measurement comprising 1000 evaluation periods
with stop condition none is performed. The measurement is started with
the INITiate command. The results can be queried using the
SAMPle...? (status RUN or RDY) or FETCh...?
(status RDY) commands. The measurement is configured via:
The <Stepmode> parameter has no effect. | |
Stop condition: SONerror
|
A single shot measurement comprising 1000 evaluation periods
with stop condition SONerror is performed. The measurement is started
with the INITiate command and stopped before the end of the
statistics cycle. The results can be queried using the SAMPle...?
(status RUN or STOP) or FETCh (status STOP)
commands. The number of bursts measured can be queried using the FETCh:<meas_obj>:STATus?
command. The measurement is configured via:
CONFigure:<meas_obj>:CONTrol:REPetitionSINGleshot,SONerror<Stepmode> The <Stepmode> parameter has no effect. |