Home Previous Next


Reduce Measurement Time

CONFigure:AFANalyzer[:PRIMary]:MTReduce <Mode>, <Frequency>

CONFigure:AFANalyzer:SECondary:MTReduce

<Mode>

Description of parameters

Def. value

Def. unit

LOWF |
EXPF

Measurement time according to lowest frequency (10 kHz)
Measurement time according to <Frequency>

LOWF

-

<Frequency>

Description of parameters

Def. value

Def. unit

10 Hz to 20 kHz

Expected frequency of the audio input signal

100

Hz

 

Description of command

FW vers.

This command is to reduce the measurement time the audio analyzer uses to calculate the measurement results (<Mode>=EXPF); see section Subsystem AFANalyzer... (Measured Values). The measurement time must be adapted to the period of the input signal, which is the reverse of the frequency. Therefore, the audio measurement can be accelerated for high-frequency signals. In the LOWF mode, <Frequency> is not taken into account.

V 3.0