Home Previous Next


Level Selection

CONFigure:MULTitone:AF1Channel:TDEFinition:MODE <Mode>

CONFigure:MULTitone:AF2Channel:TDEFinition:MODE <Mode>

<Mode>

Description of parameters

Def. value

Def. unit

SEParate | TLEVel

Use separate levels for each tone
Use total level

SEParate

-

 

Description of command

FW vers.

This command defines how the voltage of each of the test tones is determined.

  • In the default setting SEParate, the levels of all tones are defined separately and may differ from each other (see command CONFigure:MULTitone:...:TDEFinition above).
  • In the setting TLEV, the total AF generator level of 200 mV (see command CONFigure:MULTitone:...:TDEFinition:TLEVel below) is evenly distributed among all 20 enabled test tones. Test tones can still be enabled or disabled and their frequency can be changed (see CONF:MULT:...TDEF... commands above), but level settings will be ignored as long as TLEV remains effective.

V 3.0


Home Previous Next