Home Previous Next


AF Path Coupling

CONFigure:AFANalyzer[:PRIMary]:CONTrol:COUPling <Coupling>

CONFigure:AFANalyzer:SECondary:CONTrol:COUPling <Coupling>

<Coupling>

Description of parameters

Def. value

Def. unit

AC |
DC

AC coupling of AF path
DC coupling of AF path

AC ([:PRIMary] channel)
DC (:SECondary channel)

-


Description of command

FW vers.

These commands determine the AF path coupling for measurements using the AF analyzer. In firmware versions <3.05, the commands are replaced by two equivalent CONFigure:...COUPling commands.

³V 3.05


Home Previous Next